EasyManua.ls Logo

Nokia 7705 SAR - Page 142

Nokia 7705 SAR
902 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7705 SAR Interfaces
142
Interface Configuration Guide
3HE 11011 AAAC TQZZA Edition: 01
3.2.17.3.1 Single NE Management
MWA allows the 7705 SAR-8 or 7705 SAR-18 and the MPR-e radios to which it is
connected to be integrated and managed as a Single NE. The following features are
part of Single NE management:
• One Management IP Address
• MPR-e Radio Configuration Management
• MPR-e Radio Alarm Management
• MPR-e Radio Software and Upgrade Management
• MPR-e Radio Configuration Database File Management
• MPR-e Radio Inventory and Microwave Link Performance Statistics
• MPR-e Radio Reset Control
• MPR-e Radio Mute Control
One Management IP Address
The individual management and IP address of the MPR-e radios are no longer
required for network management. When managing a microwave network
(consisting of a 7705 SAR-8 or 7705 SAR-18 that is connected to one or more
MPR-e radios) using an element/network manager, only the IP address of the
7705 SAR-8 or 7705 SAR-18 needs to be entered. This capability optimizes the
microwave network’s IP addressing plan.
MPR-e Radio Configuration Management
For an MPR-e configuration, the required MWA-specific parameters are configured
on the 7705 SAR side using the CLI and the required non-MWA parameters are
configured on the MPR-e side using the MCT.
The following MWA-specific parameters are configured on the 7705 SAR side:
• 1+1 HSB parameters
• Epipe VLAN SAP parameters (in a mixed microwave link scenario, where there
is interworking between a 7705 SAR MPR-e system and an MSS 9500 MPR
system using a TDM2Ethernet service, specific MPR-e system parameters are
configured under the Epipe VLAN SAP; for more information, refer to the
7705 SAR Services Guide, “Configuring Epipe SAP Microwave Link Parameters
for Interworking with TDM2 Ethernet”).

Table of Contents