7705 SAR Interfaces
324
Interface Configuration Guide
3HE 11011 AAAC TQZZA Edition: 01
To change this parameter, all ports associated with the card must be in shutdown mode and
no channels can be defined on the card. A change in the companding law results in a
corresponding change to the signaling-type default. The signaling-type applies only to the
6-port E&M Adapter card.
Default mu-law
Parameters a-law — A-Law companding
mu-law — Mu-Law companding
signaling-type
Syntax signaling-type {type-i | type-ii | type-v}
Context config>card>mda>voice
Description This command specifies the signaling type to be used on the 6-port E&M Adapter card.
To change this parameter, all ports associated with the 6-port E&M Adapter card must be in
shutdown mode and no channels can be defined on the card.
The signaling type is selectable on a per-card basis depending on companding type. When
A-Law companding is configured, the signaling type is automatically type V. When Mu-Law
companding is configured, all signaling types can be selected; however, the only supported
configurations are both ends of the connection operating in the same mode (for example,
Type I to Type I) or one end operating in Type I mode and the other in Type V mode.
Default type-i (for Mu-Law companding)
type-v (for A-Law companding)
Parameters type-i — Type I signaling
type-ii — Type II signaling
type-v — Type V signaling