Interface Configuration Guide 7705 SAR Interfaces
Edition: 01 3HE 11011 AAAC TQZZA 403
Default n/a
input
Syntax input
Context config>port>serial>rs232>control-lead
config>port>serial>v35>control-lead
config>port>serial>x21>control-lead
Description This command enables access to the context to configure the input control leads.
Default n/a
alb-cts
Syntax alb-cts {high | low | end-to-end}
Context config>port>serial>rs232>control-lead>input
config>port>serial>v35>control-lead>input
Description This command configures the Analog Loopback (ALB) or Clear To Send (CTS) input control
lead. The input signal that is sent depends on the device-gender setting. For a DCE device,
the input signal is ALB. For a DTE device, the input signal is CTS.
This command is valid only for RS-232 and V.35 interfaces.
Default high
Parameters high — the input control lead is assumed to be on
low — the input control lead is assumed to be off
end-to-end — the input control lead follows that of the remote end. This parameter is not
supported for interface speeds 64 kb/s.
c-i
Syntax c-i {high | low | end-to-end}
Context config>port>serial>x21>control-lead>input
Description This command configures the Control (C) or Indication (I) input control lead. The input signal
that is sent depends on the device-gender setting. For a DCE device, the input signal is C.
For a DTE device, the input signal is I.
This command is valid only for an X.21 interface.