7705 SAR Interfaces
404
Interface Configuration Guide
3HE 11011 AAAC TQZZA Edition: 01
Default high
Parameters high — the input control lead is forced on
low — the input control lead is forced off
end-to-end — the input control lead follows that of the remote end
dtr-dsr
Syntax dtr-dsr {high | low}
Context config>port>serial>rs232>control-lead>input
config>port>serial>v35>control-lead>input
Description This command configures the Data Terminal Ready (DTR) or Data Set Ready (DSR) input
control lead. The input signal that is sent depends on the device-gender setting. For a DCE
device, the input signal is DTR. For a DTE device, the input signal is DSR.
This command is valid only for RS-232 and V.35 interfaces.
Default high
Parameters high — the input control lead is assumed to be on
low — the input control lead is assumed to be off
rdl-ri
Syntax rdl-ri {high | low}
Context config>port>serial>rs232>control-lead>input
Description This command configures the Remote Digital Loopback (RDL) or Ring Indicator (RI) input
control lead. The input signal that is sent depends on the device-gender setting. For a DCE
device, the input signal is RDL. For a DTE device, the input signal is RI.
This command is valid only for an RS-232 interface.
Default high
Parameters high — the input control lead is assumed to be on
low — the input control lead is assumed to be off