7705 SAR Interfaces
590
Interface Configuration Guide
3HE 11011 AAAC TQZZA Edition: 01
Table 46 Show Specific Alarm Fields
Label Description
Admin Status The administrative state of the alarm
State The current state of the alarm:
ghost: no trigger equipment presently installed
ok: no triggers are detected
alarm detected: alarm is outstanding
not monitored: alarm or all triggers are administratively
disabled
Severity The severity level for the specified alarm
Description An optional description of the alarm
Thresholds
Analog Voltage The analog voltage level threshold value for the specified
alarm, in millivolts (0.000V)
Operation The analog voltage level threshold operational value:
lt: a less-than value
gt: a greater-than value
Actions
Log Alarm Indicates whether raise/clear log events and SNMP traps
are generated for the specified alarm
Chassis Alarming Indicates whether output to chassis alarm relays and
LEDs are generated for the specified alarm
Trigger The inputs that will trigger the alarm
Type The type of trigger (a digital input or analog input, or, for
Ethernet ports, the operational state)
Admin The administrative state of the trigger