7705 SAR Interfaces
598
Interface Configuration Guide
3HE 11011 AAAC TQZZA Edition: 01
Output Example
*A:ALU-1># show external-alarms name
==========================================================================
External Alarm Names
==========================================================================
Name Alarm/Relay Type Admin Value State
--------------------------------------------------------------------------
ainput1 alarm-1/1.a-1 analog-in up 0.0 V ok
ainput2 alarm-1/1.a-2 analog-in up 0.0 V ok
dinput1 alarm-1/1.d-1 digital-in up open ok
dinput2 alarm-1/1.d-2 digital-in up open ok
dinput23 alarm-1/1.d-23 digital-in up open ok
dinput24 alarm-1/1.d-24 digital-in up open ok
dinput3 alarm-1/1.d-3 digital-in up open ok
dinput4 alarm-1/1.d-4 digital-in up open ok
output1 relay-1/1.d-1 digital-out down off
output2 relay-1/1.d-2 digital-out down off
output3 relay-1/1.d-3 digital-out down off
output4 relay-1/1.d-4 digital-out down off
output5 relay-1/1.d-5 digital-out down off
==========================================================================
*A:ALU-1>#
Table 51 Show External Alarm Name Fields
Label Description
External Alarm Names
Name The alarm name
Alarm/Relay The name of the alarm input or output relay
Type The alarm input type (digital input, analog input, or
oper-state) or output relay type (digital output)
Admin The administrative state of the alarm input or output relay

Table of Contents