Interface Configuration Guide 7705 SAR Interfaces
Edition: 01 3HE 11011 AAAC TQZZA 597
Output Example
*A:ALU-1># show external-alarms output relay-1/1.d-1 detail
==============================================================================
Output relay-1/1.d-1 Detail
==============================================================================
Name : output1
Admin Status : down State : off
Description : Digital Output Relay
==============================================================================
*A:ALU-1>#
Table 50 Show External Alarm Output Detail Fields
Label Description
Output relay-x/x.d-x Detail
Name The name of the output relay
Admin The administrative state of the alarm output relay
When the digital output relay output state is set to no
shutdown, the normally closed contacts open and the
normally open contacts close. The digital output displays
a digital output administrative status of up and the state
of active (the output relay is energized).
When the digital output relay output state is set to
shutdown, the normally closed contacts close and the
normally open contacts open. The digital output displays
a digital output administrative status of down and the
state of off (the output relay is not energized).
State The current state of the alarm output relay:
ghost: no equipment is installed
off: the output relay is not energized (it is administratively
disabled)
active: the output relay is energized (active)
Description The description for the output relay