7705 SAR Interfaces
666
Interface Configuration Guide
3HE 11011 AAAC TQZZA Edition: 01
Transceiver type The following information is provided for a configured
SFP:
• model number
• TX laser wavelength
• whether it is diagnostics capable
• connector code
• vendor organizationally unique identifier (OUI)
• manufacture date
•media
• serial number
• part number
• optical compliance
• link length support:
• whether it is Sync-E capable
Transceiver Digital Diagnostic Monitoring (DDM), Externally Calibrated
SFP manufacturers specifications guidelines contained
in specification SFF-8472, for the following:
• temperature (C)
• supply voltage (V)
• Tx bias current (mA)
• Tx output power (dBm)
• Rx optical power (avg dBm)
For the above categories, the following values are
shown:
• Value is the current measured value of each variable
• High Alarm is the measurement of Value that will
cause a DDM High Alarm to be output
• High Warn is the measurement of Value that will
cause a DDM High Warning Alarm to be output
• Low Warn is the measurement of Value that will
cause a DDM Low Warning Alarm to be output
• Low Alarm is the measurement of Value that will
cause a DDM Low Alarm to be output
If alarms/warnings are raised, there will be an "!" in the
output
Table 67 Show Port Detail Output Fields (Ethernet, Access Mode)
Label Description