EasyManua.ls Logo

Nokia 7705 SAR - Page 666

Nokia 7705 SAR
902 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7705 SAR Interfaces
666
Interface Configuration Guide
3HE 11011 AAAC TQZZA Edition: 01
Transceiver type The following information is provided for a configured
SFP:
• model number
• TX laser wavelength
• whether it is diagnostics capable
• connector code
• vendor organizationally unique identifier (OUI)
• manufacture date
•media
• serial number
• part number
• optical compliance
• link length support:
• whether it is Sync-E capable
Transceiver Digital Diagnostic Monitoring (DDM), Externally Calibrated
SFP manufacturers specifications guidelines contained
in specification SFF-8472, for the following:
• temperature (C)
• supply voltage (V)
• Tx bias current (mA)
• Tx output power (dBm)
• Rx optical power (avg dBm)
For the above categories, the following values are
shown:
• Value is the current measured value of each variable
• High Alarm is the measurement of Value that will
cause a DDM High Alarm to be output
• High Warn is the measurement of Value that will
cause a DDM High Warning Alarm to be output
• Low Warn is the measurement of Value that will
cause a DDM Low Warning Alarm to be output
• Low Alarm is the measurement of Value that will
cause a DDM Low Alarm to be output
If alarms/warnings are raised, there will be an "!" in the
output
Table 67 Show Port Detail Output Fields (Ethernet, Access Mode)
Label Description

Table of Contents