7705 SAR Interfaces
726
Interface Configuration Guide
3HE 11011 AAAC TQZZA Edition: 01
i-c The Indication/Control output control lead (applicable
only for X.21 interfaces)
Cfg The configuration of the output signaling leads:
• high: the output control lead is forced on
• low: the output control lead is forced off
• end-to-end: the input control lead follows that of the
remote end. It can only be configured when the
interface speed is <64 kb/s and is only applicable on
the following control leads:
− dcd-rts
− cts-alb – follows that of the remote end except
when the output control lead is carrying a CTS
signal on an RS-232 port operating at subrate
speeds. In this case, the control lead follows
the HCM status:
• if the HCM status is Up, the CTS output
control lead is 1
• if the HCM status is Down, the CTS output
control lead is 0
− i-c
Netw The value that indicates the current states of the input
and output control leads. These values are transported
over the network; therefore, are referred to as network-
side values:
• 0 indicates low
• 1 indicates high
• blank indicates unknown (for example, due to a
shutdown)
Line The value that indicates the current signal levels of the
input and output control leads connected to the attached
CPE. These values are signaled over the (physical) line;
therefore, are referred to as line-side values:
• 0 indicates low
• 1 indicates high
• blank indicates unknown (for example, due to a
shutdown)
Mon Indicates whether monitoring is enabled (on) or disabled
(off) for the control lead; applies to input control leads
only
Table 74 Show Port Serial Channel Output Fields (Continued)
Label Description