45530603TH Rev.2
5-47
Oki Data CONFIDENTIAL
5. MAINTENANCE MENUS
Pressing the BACK button returns to the display of “WIDTH SNS ADJ RSLT”.
(7) Pressing the CANCEL button during the test cancels the test, restoring the state of
step 2
When WIDTH SNS ADJ RSLT (Reference to the results of paper width sensor
sensitivity adjustment) is performed
(1) After pressing the MENU
or MENU
button until the following is displayed in the
above step 2, press the OK button.
PAPER WIDTH SNS ADJ
WIDTH SNS ADJ RSLT
Same operation as in (6) of the above “WIDTH SNS ADJ EXE”
When WIDTH ADJ PAR-SET (paper width setting of adjustment media) is performed
This is used when sensitivity adjustment is performed using media other than A4-LEF.
(2) After pressing the MENU
or MENU
button until the following is displayed in the
above step 2, press the OK button.
PAPER WIDTH SNS ADJ
WIDTH ADJ PAR-SET
(3) Pressing the OK button under the following condition enters the entry mode, and then,
enter a desired value.
(For how to enter, refer to the Table 5-8-2)
ADJUST PAPER WIDTH
**** (W=***.*mm)
(4) Press the BACK button to return to the (1).
(5) Repeat the steps (1) to (3) as necessary.
4. Repeat the step 2, as necessary.
5. Press the BACK button to end the test. (restoring the state of the step 1)
Table 5-8-1
PAPER WIDTH SNS ADJ Selection Items
SUB MENU Details Handling of results
WIDTH ADJ PAR-SET Sets the paper width of the
adjustment media.
* The default is A4-LEF.
For displayed items, refer to the
table 5-8-2
WIDTH SNS ADJ EXE Executes the paper-
width sensor sensitivity
adjustment.
OK: Writes the adjustment value
in EEPROM.
NG: Displays an error and updates
RESULT only.
WIDTH SNS ADJ RSLT Refers to the result of
the paper-width sensor
sensitivity adjustment.
For displayed items, refer to the
Table 5-8-5
Table 5-8-2 WIDTH ADJ PAR-SET Selection Items
Upper line of the
display
Lower line of the
display
Details Memory
WIDTH ADJ PAR-
SET
**** (W=***.*mm) Sets the width of adjustment media.
Settable range: 64.0mm to 336.2mm
Default: 297.0mm (A4-LEF) (Note1)
W: Width of adjustment media
SRAM
* Set items are effective for this test mode only. (Not written in EEPROM)
(Note1) When pressing numerical keys [0]-[9], a number is entered in a blinking digit.
When pressing the MENU
button, a blinking digit is incremented.
When pressing the MENU
button, a blinking digit is decremented.
Every time pressing the CANCEL button, a blinking digit of the setting value moves to the
right.
Every time pressing the ONLINE button, a blinking digit of the setting value moves to the
left.

Table of Contents

Other manuals for Oki C911