EasyManua.ls Logo

Olympus RollerFORM User Manual

Olympus RollerFORM
168 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
DMTA-20073-01EN — Rev. C
November 2015
RollerFORM Scanner
Phased Array Wheel Probe
Users Manual
This instruction manual contains essential information on how to use this Olympus product safely and effectively.
Before using this product, thoroughly review this instruction manual. Use the product as instructed.
Keep this instruction manual in a safe, accessible location.

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Olympus RollerFORM and is the answer not in the manual?

Olympus RollerFORM Specifications

General IconGeneral
BrandOlympus
ModelRollerFORM
CategoryLaboratory Equipment
LanguageEnglish

Summary

Important Information — Please Read Before Use

Instrument Compatibility

Lists ancillary equipment compatible with the RollerFORM scanner.

Repair and Modification

Safety Symbols

Safety Signal Words

DANGER

Indicates an imminently hazardous situation leading to death or serious injury.

WARNING

Indicates a potentially hazardous situation leading to death or serious injury.

Safety Precautions

Warnings

General Warnings

Provides critical safety instructions for instrument operation and maintenance.

Electrical Warnings

Details safety requirements for connecting the instrument to a power source.

1. RollerFORM Scanner Overview

1.1 RollerFORM

1.2 Acoustic Wheel

1.3 Wheels

2. Setting Up the Instrument

2.1 Connecting the RollerFORM Scanner to the Instrument

Instructs on connecting the scanner via LEMO connector to instruments like OmniScan or TomoScan.

2.2 Setting Up the Instrument

Explains how to set up the scanner using predefined USB key configurations.

2.3 Setting Up the Indexer Clicker

Guides on configuring the Indexer Clicker in OmniScan MXU software for scan indexing.

2.4 Setting Up the Start Acquisition Button

Explains how to configure the Start Acquisition button in OmniScan MXU software.

3. Preparing the RollerFORM Liquid Chamber

3.1 Filling the Acoustic Wheel’s Liquid Chamber

Details filling the chamber with appropriate liquid, using the manual pump.

3.2 Removing Air Bubbles from the Liquid Chamber

Explains how to remove air bubbles using the built-in bubble trap.

4. Preparing for an Inspection

4.2 Optimizing the Phased Array Signal

Details adjusting probe angle relative to the surface for optimal signal.

4.3 Adjusting the Middle Wheel

Explains how to adjust the middle wheel based on surface characteristics and scan direction.

5. Performing an Inspection

6. Maintenance

6.1 Removing the Acoustic Wheel from the RollerFORM Scanner

Details procedures for removing the acoustic wheel for cleaning or replacement.

6.2 Emptying the Acoustic Wheel’s Liquid Chamber

Explains how to empty the liquid chamber before maintenance or tire replacement.

6.3 Changing the Probe-Axle

Covers procedures for removing and installing the probe-axle.

6.8 Changing the Mini-Wheel Encoder

Provides instructions for replacing or relocating the Mini-Wheel encoder.

6.11 Adjusting the Angle of the Guiding Laser Beam

Describes how to verify and adjust the laser beam alignment.

7. Specifications

8. Spare Parts

Related product manuals