Page #153 background image
Outputting/Controlling with Ethernet
FQ-CR2 User’s Manual
151
8
Communications with External Devices
Communications Example
An example of the communications log when a computer is connected and communications is performed with
a no-protocol command from a terminal application is shown below.
Example 1: Changing Scenes (Scene number 1 is specified.)
Example 2: Acquiring inspection item data (Acquires the judgement result for a 2D-code registered to
inspection item 10.)
Example 3: Measurement when Ethernet Output Is Not Set
Example 4: Measurement when Ethernet Output Is Set
S 1
OK
ITEMDATA
10 0
0
OK
M
OK
M
OK
1.0000 0.0000 0.0000 306.0000
M
OK
2.0000 0.0000 0.0000 0.0000