Highspeed Counter/Pulse Output/ PWM OutputFP0
9 17
9.3 Highspeed Counter Function
Positioning operations with a double speed inverter
When X5 is turned on, Y0 and Y1 turn on and the conveyor begins moving. When the
elapsed value (DT9044 and DT9045) reaches K4500, Y1 turns off and the conveyor
begins decelerating. When the elapsed value reaches K5000, Y0 turns off and the
conveyor stops.
R101
DF
X5
R100
R100
R903A R103
DF
R100
R101
DF/
R903A
R103
R103
R100
T0
TMX 0, K 5
R101 Y0
S
Y1
S
F61 DCMP, K 4500, DT 9044
R100
DF
R102
Y1
R
R100
R102
R900C
F1 DMV, K 0, DT 9044
F167 HC1R, K 0, K 5000, Y 0
Highspeed signal to inverter
Reaches deceleration point
Deceleration
Completion pulse (0.5 seconds)
Positioning operations running
Positioning operations start
Start signal to inverter