Functions for Safety Measures
This laser marker has the functions shown below for safety measures.
Head Section
1. Shutter Lever
The laser can be radiated with the shutter opened, or it cannot be radiated with the shutter closed. Howevr, the
guide laser is available.
2. Laser Radiation Indicator
The indicator lights in red for 0.5 seconds just after the power supply is turned ON. Then, it lights in blue
during trigger standby.
The color of the indicator is changed into red during marking.
3. File No./Error Code Display: FILE No./ERROR CODE
The selected file No. is displayed. When an error occurs, the corresponding error code is displayed as well.
Refer to “5 Troubleshooting” (P.187) for details of error code.
During excitation of the laser (approx. 15 seconds), the product is not ready for radiating laser.