165
Operation Related to Counter
In case of the counter initial value of the counter is 1 with counter step 1:
Input COUNTER RESET with holding the input status of the file selection (D0 to D6).
(When the file No. changing command (FNO) is set by RS-232C, input of D0 to D6 is not
required.)
READY Output
TRIG Input
Counter Reset
Input
Counter End
Input
OFF
ON
OFF
ON
OFF
ON
OFF
ON
Counter End
Value
Counter:
End value-1
Counter
Value: 1
Counter
Value: 2
Counter
Value: 3
Counter
Value: 1