890SD Standalone Drive
Page 5-40 890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
8
9
10
11
A
B
C
D
1
2
3
4
5
6
7
E
SET-UP PARAMETERS
PREF
6511/6901
Display
Default Brief Description
V/Hz SV CLV 4-Q PMAC
27.06
MAG CURRENT
product code
dependent
Rotating Autotune sets
actual value
Enter the No-Load
Amps from the motor
nameplate
x x x
27.14
STATOR RES
product code
dependent
Autotune sets actual
value
Motor per-phase stator
resistance
x x
27.15
LEAKAGE
INDUC
product code
dependent
Autotune sets actual
value
Motor per-phase stator
leakage inductance
x x
27.16
MUTUAL
INDUC
product code
dependent
Autotune sets actual
value
Motor per-phase stator
mutual (magnetising)
inductance
x x
27.17
ROTOR TIME
CONST
product code
dependent
Autotune sets actual
value
The motor model rotor
time constant as
determined by
Autotune
x x