890SD Standalone Drive
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D Page 5-3
8
9
10
11
A
B
C
D
1
2
3
4
5
6
7
E
Main Points
♦ This is a cubicle-mounted unit. It is not suitable for wall-mounting.
♦ Mount 890's side-by-side vertically on a solid, flat, normally cool, non-flammable, vertical surface.
♦ The unit(s) can be DIN rail or panel mounted.
♦ Fit the 890 Installation kit to the bottom of the drive.
♦ Adequate ventilation must be provided.
♦ Avoid excessive vibration.
♦ The earth points (D, E, G, M & S) are shown separated - it may be possible to use one large star point
without EMC problems, this will depend upon your application.
Note Refer to Appendix C for information about EMC compliance.
Sizing the Enclosure
The enclosure should comply with the European safety standards VDE 0160 (1994)/EN50178 (1998) and
will require a tool for opening.
The size of the enclosure will depend on many factors:
♦ Physical size and number of units
♦ Ventilation clearances
♦ Power output, affected by derating due to altitude and ambient temperature

Table of Contents

Other manuals for Parker ac890

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker ac890 and is the answer not in the manual?

Parker ac890 Specifications

General IconGeneral
BrandParker
Modelac890
CategoryDC Drives
LanguageEnglish

Related product manuals