Technical Specifications
Page
E-8
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
8
9
10
11
A
B
C
D
1
2
3
4
5
6
7
E
Electrical Ratings: 890CS Frame D, 500V
Output current must not be exceeded under steady state operating conditions.
FRAME D : 108A AC rms Input Current (nominal power 60kW)
Model Number
890CS/5/0108D
Operating Voltage
208V to 500V ±10%
Nominal Operating Voltage
V 208/230 380/415 460 500
Input Current
A 108
Continuous RMS Output Current
A 135
Output Power
30kW/40HP 60kW 90HP 75kW
Power Loss
W 300 300 300 300
Output Overload
150% overload for 60 seconds
Dynamic Brake Current Rating
A 75 75 75 75
Input Bridge I
2
t
A
2
s 108,000
Prospective Short Circuit Current
kA 100
FRAME D : 162A AC rms Input Current (nominal power 90kW)
Model Number
890CS/5/0162D
Operating Voltage
208V to 500V ±10%
Nominal Operating Voltage
V 208/230 380/415 460 500
Input Current
A 162
Continuous RMS Output Current
A 200
Output Power
45kW/60HP 90kW 135HP 110kW
Power Loss
W 500 500 500 500
Output Overload
150% overload for 60 seconds
Dynamic Brake Current Rating
A 100 100 100 100
Input Bridge I
2
t
A
2
s 128,000
Prospective Short Circuit Current
kA 100