Programming
Page
D-84
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
8
9
10
A
B
C
D
E
1
2
3
4
5
6
7
MOTOR PMAC 1
SETUP::MOTOR CONTROL::MOTOR PMAC 1
Designed for PMAC Control Mode.
The MOTOR PMAC blocks (1 & 2) store all the parameters needed to run a PMAC Motor. These parameter values are entered
automatically by the DSE 890 Configuration Tool when the tool is used to select the motor type.
In order for the drive to control the motor the parameters marked ● MUST be set.
Parameter Descriptions
MANUFACTURER
PREF: 134.01 Default: PARVEX Range:
Enter the motor manufacturer's name.
MODEL
PREF: 134.02 Default: HS620EV Range:
Enter the motor name.
● CONSTRUCTION
PREF: 134.03 Default: 0 Range: See below
Select the motor’s construction type.
Enumerated Value : Construction
0 : AXIS Standard motor.
1 : SPINDLE Spindle motor.
2 : TORQUE Direct torque motor.
ATMOSPHERE
PREF: 134.04 Default: 0 Range: See below
Selct the motor’s atmospheric details.
Enumerated Value : Atmosphere
0 : STANDARD Standard motor.