EasyManuals Logo

Parker ac890 Reference Manual

Parker ac890
640 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #605 background imageLoading...
Page #605 background image
Technical Specifications
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D Page
E-7
8
9
10
11
A
B
C
D
1
2
3
4
5
6
7
E
Electrical Ratings: 890CS Frame B, 500V
Output current must not be exceeded under steady state operating conditions.
FRAME B : 32A AC rms Input Current (nominal power 15kW)
Model Number
890CS/5/0032B
Operating Voltage
208V to 500V ±10%
Nominal Operating Voltage
V 208/230 380/415 460 500
Input Current
A 32
Continuous RMS Output Current
A 40
Output Power
7.5kW/10HP 15kW 25HP 18kW
Power Loss
W 105 105 105 105
Output Overload
150% overload for 60 seconds
Dynamic Brake Current Rating
A 20 20 20 20
Input Bridge I
2
t
A
2
s 1000
Prospective Short Circuit Current
kA 65
FRAME B : 54A AC rms Input Current (nominal power 30kW)
Model Number
890CS/5/0054B
Operating Voltage
208V to 500V ±10%
Nominal Operating Voltage
V 208/230 380/415 460 500
Input Current
A 54
Continuous RMS Output Current
A 65
Output Power
15kW/20HP 30kW 45HP 37kW
Power Loss
W 195 195 195 195
Output Overload
150% overload for 60 seconds
Dynamic Brake Current Rating
A 40 40 40 40
Input Bridge I
2
t
A
2
s 1500
Prospective Short Circuit Current
kA 65

Table of Contents

Other manuals for Parker ac890

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker ac890 and is the answer not in the manual?

Parker ac890 Specifications

General IconGeneral
BrandParker
Modelac890
CategoryDC Drives
LanguageEnglish

Related product manuals