Operating the Drive
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D Page 7-45
8
9
10
11
A
B
C
D
1
2
3
4
5
6
7
E
3% Choke
Motor
Power
Input
Voltage
Choke Inductance Currents
Drive
Frame
Size
(kW/Hp) (V)
(μH)
50Hz 1kHz 2.5kHz Sum
B 4/5 230 CO468341U004 854 14.95 0.39 0.00 15
C 7.5/10 230 CO468341U011 503 25.38 0.66 0.00 26
D 18.5/25 230 CO468341U018 208 61.63 1.59 0.00 62
E 22/30 230 CO468341U030 177 72.50 1.87 0.00 73
F 45/60 230 CO468341U055 92 139.57 3.60 0.00 140
B 6/10 400 CO468325U006 1750 12.69 0.33 0.00 13
C 15/20 400 CO468325U018 817 27.19 0.70 0.00 28
D 30/40 400 CO468325U037 416 53.47 1.38 0.00 54
E 45/60 400 CO468325U055 282 78.85 2.04 0.00 79
F 90/150 400 CO468325U110 137 163.13 4.21 0.00 164
G 180/300 400 CO468325U220 68 327.17 8.45 0.00 328
H 280/450 400 CO468325U315 48 471.28 12.17 0.00 472
J 315/500 400 CO468325U355 42 534.72 13.81 0.00 535
Note: Lower values for THD of current can be achieved by adding extra line impedance.