Page #25 background image
890CS & 890CD Common Bus Units
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D Page
4-5
8
9
10
11
A
B
C
D
1
2
3
4
5
6
7
E
8
9
1
2
3
4
5
6
E
890 Operating Conditions
Humidity
Maximum 85% relative humidity at 40°C (104°F) non-condensing
Atmosphere Non flammable, non corrosive and dust free
Climatic Conditions Class 3k3, as defined by EN50178 (1998)
Vibration The product has been tested to the following specification:
Test Fc of EN60068-2-6
10Hz<=f<=57Hz sinusoidal 0.075mm amplitude
57Hz<=f<=150Hz sinusoidal 1g
10 sweep cycles per axis on each of three mutually perpendicular axis
Safety
Pollution Degree
Pollution Degree ll (non-conductive pollution, except for temporary
condensation)
Europe
When fitted inside an enclosure, this product conforms with the Low
Voltage Directive 73/23/EEC with amendment 93/68/EEC, Article 13
and Annex III using EN50178 (1998) to show compliance.
North America/ Canada
Complies with the requirements of UL508C as an open-type drive.

Table of Contents

Other manuals for Parker ac890

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker ac890 and is the answer not in the manual?

Parker ac890 Specifications

General IconGeneral
BrandParker
Modelac890
CategoryDC Drives
LanguageEnglish

Related product manuals