Sequencing Logic
Page B-10 890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
8
9
10
11
A
B
C
D
1
2
3
4
5
6
7
E
(Not) Disable Voltage
ANDed with the NOT COAST STOP parameter of the SEQUENCING LOGIC function block.
When both Set (=1) is the same as:
NOT COAST
STOP
= TRUE
When either or both Cleared (= 0) is the same as :
NOT COAST
STOP
= FALSE
(Not) Quick Stop
ANDed with the NOT FAST STOP parameter on the SEQUENCING LOGIC function block.
When both Set (=1) is the same as:
NOT FAST STOP = TRUE
When either or both Cleared (= 0) is the same as :
NOT FAST STOP = FALSE
Enable Operation
ANDed with the DRIVE ENABLE parameter on the SEQUENCING LOGIC function block.
When both Set (=1) is the same as:
DRIVE ENABLE = TRUE
When either or both Cleared (= 0) is the same as :
DRIVE ENABLE = FALSE