Programming
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D Page
D-137
8
9
10
A
B
C
D
E
1
2
3
4
5
6
7
Parameter Descriptions
INIT DONE
PREF: 133.17 Default: TRUE Range: FALSE / TRUE
This is a diagnostic output indicating the state of the resolver init sequence:
INIT DONE = FALSE : init on going
INIT DONE = TRUE : init done
REVERSE CNT DIR
PREF: 133.18 Default: FALSE Range: FALSE / TRUE
Set the count direction for the resolver feedback.
REVERSE CNT DIR = FALSE : the position is increasing if the motor is running in a clockwise direction looking to the front
shaft of the motor.
REVERSE CNT DIR = TRUE : the position is decreasing if the motor is running in a clockwise direction looking to the front
shaft of the motor.
SPEED FILTER
PREF: 133.19 Default: 100.00 Range: 10.00 to 1000.00 Hz
Set the low pass filter frequency in Hz on the resolver speed information.