D-174
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
8
9
10
A
B
C
D
E
1
2
3
4
5
6
7
The DISABLED WORD 2 , ACTIVE WORD 2 and WARNINGS WORD 2 parameters use a four digit hexadecimal number
to identify individual trips. Each trip has a unique corresponding number as shown below.
Trip Name (MMI) Value Mask + User Disable Auto-restart
NO TRIP 0 0x0000 N/A N/A
MOTOR OVERTEMP 1 0x0001 Yes Yes
CURRENT LIMIT 2 0x0002 No Yes
TRIP 19 (Reserved)
4 0x0004 No No
24V FAILURE 8 0x0008 Yes Yes
LOW SPEED OVER I 16 0x0010 No Yes
PHASE FAIL 32 0x0020 No Yes
ENCODER 1 FAULT 64 0x0040 Yes Yes
DESAT (OVER I) 128 0x0080 No Yes
VDC RIPPLE 256 0x0100 No Yes
BRAKE SHORT CCT 512 0x0200 No Yes
OVERSPEED 1024 0x0400 Yes Yes
ANALOG INPUT ERR
2048 0x0800 No Yes
INT DB RESISTOR 4096 0x1000 No Yes
TRIP 30 (Reserved)
8192 0x2000 No No
UNKNOWN 16384 0x4000 No Yes
OTHER 32768 0x8000 No Yes