Programming
Page
D-176
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
8
9
10
A
B
C
D
E
1
2
3
4
5
6
7
The DISABLED WORD 4 , ACTIVE WORD 4 and WARNINGS WORD 4 parameters use a four digit hexadecimal number
to identify individual trips. Each trip has a unique corresponding number as shown below.
Trip Name (MMI) Value Mask EXT 1+ User Disable Auto-restart
NO TRIP 0 0x0000 N/A N/A
OUTPUT GBX ERROR 1 0x0001 Yes N/A
APP HALTED 2 0x0002 N/A N/A
APP ERROR 4 0x0004 N/A N/A
FIRMWARE ERROR 8 0x0008 N/A N/A
TRIP 53 (Reserved)
16 0x0010 N/A N/A
TRIP 54 (Reserved)
32 0x0020 N/A N/A
TRIP 55 (Reserved)
64 0x0040 N/A N/A
TRIP 56 (Reserved)
128 0x0080 N/A N/A
RESOLVER ERROR 256 0x0100 N/A N/A
I2T MOTOR TRIP 512 0x0200 N/A N/A
TRIP 59 (Reserved)
1024 0x0400 N/A N/A
SAFE TORQUE OFF 2048 0x0800 N/A N/A
TRIP 63 (Not Affected)
16384 0x4000 N/A N/A
TRIP 64 (Not Affected)
32768 0x8000 N/A N/A