PREF Name Block Type Range Default ro\rw Notes
64.04 READ ONLY OPERATOR MENU 32 BOOL 0 : FALSE
1 : TRUE
FALSE rw
64.05 IGNORE PASSWORD OPERATOR MENU 32 BOOL 0 : FALSE
1 : TRUE
FALSE rw
65.01 DECIMAL PLACE DISPLAY SCALE 1 ENUM 0 : DEFAULT
1 : X.XXXX
2 : X.XXX
3 : X.XX
4 : X.X
5 : X.
DEFAULT rw
65.02 FORMULA DISPLAY SCALE 1 ENUM 0 : A/B * X + C
1 : A/B * (X+C)
2 : A/(B * X) + C
3 : A/(B * (X+C))
A/B * X + C rw
65.03 COEFFICIENT A DISPLAY SCALE 1 REAL -32768.0000 to 32767.0000 1.0000 rw
65.04 COEFFICIENT B DISPLAY SCALE 1 REAL -32768.0000 to 32767.0000 1.0000 rw
65.05 COEFFICIENT C DISPLAY SCALE 1 REAL -32768.0000 to 32767.0000 0.0000 rw
65.06 HIGH LIMIT DISPLAY SCALE 1 REAL -32768.0000 to 32767.0000 0.0000 rw
65.07 LOW LIMIT DISPLAY SCALE 1 REAL -32768.0000 to 32767.0000 0.0000 rw
65.08 UNITS DISPLAY SCALE 1 STRING max length is 6 chars rw
66.01 DECIMAL PLACE DISPLAY SCALE 2 ENUM 0 : DEFAULT
1 : X.XXXX
2 : X.XXX
3 : X.XX
4 : X.X
5 : X.
DEFAULT rw
66.02 FORMULA DISPLAY SCALE 2 ENUM 0 : A/B * X + C
1 : A/B * (X+C)
2 : A/(B * X) + C
3 : A/(B * (X+C))
A/B * X + C rw
66.03 COEFFICIENT A DISPLAY SCALE 2 REAL -32768.0000 to 32767.0000 1.0000 rw