Programming
Page
D-236
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
8
9
10
A
B
C
D
E
1
2
3
4
5
6
7
PREF Name Block Type Range Default ro\rw Notes
130.01 BAUDRATE DEVICENET ENUM 0 : 125K
1 : 250K
2 : 500K
3 : INVALID
125K ro Output
130.02 MAC ID DEVICENET INT _ 63 ro Output
130.03 CONNECTION STATE DEVICENET ENUM 0 : NON EXISTENT
1 : SELFTEST
2 : STANDBY
3 : OPERATIONAL
4 : RECOVER FAULT
5 : UNRECOVER FAULT
NON
EXISTENT
ro Output
130.04 DEVICE STATUS DEVICENET ENUM 0 : NO ERROR
1 : OWNED
2 : CONFIGURED
3 : MINOR REC FAULT
4 : MINOR UNREC FLT
5 : MAJOR REC FAULT
6 : MAJOR UNREC FLT
NO ERROR ro Output
130.05 HARDWARE DEVICENET BOOL 0 : FALSE
1 : TRUE
FALSE ro Output
130.06 BAUDRATE SOFT DEVICENET ENUM 0 : 125K
1 : 250K
2 : 500K
125K rw
130.07 MAC ID SOFT DEVICENET INT 1 to 63 0 rw
133.01 NAME RESOLVER STRING max length is 16 chars rw 2
133.02 POLES RESOLVER INT 2 to 20 2 rw 2
133.03 RATIO RESOLVER REAL 0.20 to 1.00 0.50 rw
133.04 SPEED MAX RESOLVER INT 0 to 2147483647 10000 rw 2
133.05 ACCURACY RESOLVER REAL 0.00 to 60.00 20.00 rw 2
133.06 CARRIER VOLTAGE RESOLVER REAL 5.00 to 10.00 V 7.00 V rw 2
133.07 CURRENT RESOLVER REAL 0.000 to 0.100 A 0.046 A rw 2