PREF Name Block Type Range Default ro\rw Notes
135.07 SPEED AT MPS1 MOTOR PMAC 2 INT 0 to 2147483647 2300 rw 2
135.08 SPEED AT MPS2 MOTOR PMAC 2 INT 0 to 2147483647 4000 rw 2
135.09 SPEED AT MPS3 MOTOR PMAC 2 INT 0 to 2147483647 4800 rw 2
136.01 DRIVE NAME DRIVE CONFIG STRING max length is 14 chars 890 DRIVE rw 2
136.02 CONTROL MODE DRIVE CONFIG ENUM 0 : VOLTS / Hz
1 : SENSORLESS VEC
2 : CLOSED-LOOP VEC
3 : 4-Q REGEN
4 : PMAC
VOLTS / Hz rw
136.03 FBK OPT TYPE DRIVE CONFIG ENUM 0 : NONE
1 : ENCODER
2 : RESOLVER
3 : TYPE 3
4 : TYPE 4
5 : TYPE 5
6 : TYPE 6
7 : TYPE 7
NONE rw 2
136.04 SLOT A OPT TYPE DRIVE CONFIG ENUM 0 : NONE
1 : RS485
2 : PROFIBUS
3 : LINK
4 : DEVICE NET
5 : CAN OPEN
6 : LONWORKS
7 : CONTROLNET
8 : MODBUS PLUS
9 : ETHERNET
10 : HTTL INC. ENC.
11 : RS485 INC. ENC.
12 : ENDAT SIN/COS
13 : TYPE 13
14 : TYPE 14
15 : TYPE 15
NONE rw 2