Programming
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D Page
D-245
8
9
10
A
B
C
D
E
1
2
3
4
5
6
7
PREF Name Block Type Range Default ro\rw Notes
161.01 I2T INHIBIT MOT PMAC PROTECT BOOL 0 : FALSE
1 : TRUE
FALSE rw
161.02 I2T LIMIT MOTOR MOT PMAC PROTECT BOOL 0 : FALSE
1 : TRUE
FALSE ro Output
161.03 I2T MOTOR LOAD MOT PMAC PROTECT REAL _.x 0.0 % ro Output
161.04 MOTOR I2T TRIP MOT PMAC PROTECT BOOL 0 : FALSE
1 : TRUE
FALSE ro Output
162.01 AIMING POINT INVERS TIME PMAC REAL 50.00 to 105.00 % 105.00 % rw
162.02 DELAY INVERS TIME PMAC REAL 0.5 to 4.0 s 4.0 s rw
162.03 DOWN TIME INVERS TIME PMAC REAL 0.5 to 2.0 s 1.0 s rw
162.04 UP TIME INVERS TIME PMAC REAL 0.5 to 2.0 s 1.0 s rw
162.05 IT LIMITING INVERS TIME PMAC BOOL 0 : FALSE
1 : TRUE
FALSE ro Output
162.06 INVERSE TIME OP INVERS TIME PMAC REAL _.xx 0.00 % ro Output
162.07 IT WARNING INVERS TIME PMAC BOOL 0 : FALSE
1 : TRUE
FALSE ro Output
163.01 SELECT TQ COMP 2 SPEED LOOP 2 ENUM 0 : NONE
1 : MAX ATTENUATION
2 : MINIMUM PHASE
3 : NOTCH FILTER
NONE rw 2
163.02 TQ COMP 2 FREQ SPEED LOOP 2 REAL l 100 to l 8000 Hz 2000 Hz rw
163.03 SELECT TQ COMP 3 SPEED LOOP 2 ENUM 0 : NONE
1 : MAX ATTENUATION
2 : MINIMUM PHASE
3 : NOTCH FILTER
NONE rw 2
163.04 TQ COMP 3 FREQ SPEED LOOP 2 REAL l 100 to l 8000 Hz 2000 Hz rw
165.01 CUST ALARM 1 CUSTOM TRIPS BOOL 0 : FALSE
1 : TRUE
FALSE rw
165.02 CUST ALARM 2 CUSTOM TRIPS BOOL 0 : FALSE
1 : TRUE
FALSE rw