Technical Specifications
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D Page
E-5
8
9
10
11
A
B
C
D
1
2
3
4
5
6
7
E
Model Number
Block Variable Description
6 X One character specifying the Perfomance Level:
S = Standard - Velocity/Torque Applications
Basic LINK macro blocks: (Math Functions, PID, Boolean, Simple Winder).
Induction and PM Servo Motors Supported
A = Advanced - Standard Level plus:
Advanced LINK macro blocks such as SPW/CPW winder control and Electronic
Gearing. Industry standard motion commands supported such as Move
Incremental, Move Absolute etc... PLCOpen(like) programming environment.
H = High Performance - Advanced Level plus:
Application specific LINK macro blocks to include, Camming, Cut-to-Length
and Shaftless Printing.
N = Not Applicable for CS & CA Units
7 XX Two characters specifiying the destination:
EN = English, 50/60Hz (890CS and 890CA units only)
FR = France 50Hz (50/60Hz if CA or CS)
GR = Germany 50Hz (50/60Hz if CA or CS)
IT = Italy 50Hz (50/60Hz if CA or CS)
SW = Sweden 50Hz (50/60Hz if CA or CS)
UK = United Kingdom, 50Hz (890CD and 890SD units only)
US = United States, 60Hz (890CD and 890SD units only)
8 XX Two characters specifiying the livery (Brand Label Partners - 01 thru 99):
00 = SSD Standard
9 XX Two characters specifiying special options:
00 = None fitted