Hunter-Pro Series & Captain 8 Installation Guide
6.5.4 Communication Options
A telephone line is connected to to the control panel
The control panel will make calls without checking for a dial tone first
(usuful when the line is noisy).
The dial tone is checked every 60 seconds while the panel is armed.
Because the panel continuously checks the line voltage, it is
recommended to use this feature only when necessary.
The dial tone is checked every 60 seconds while the panel is
disarmed. Because the panel continuously checks the line voltage, it
is recommended to use this feature only when necessary.
“+”: Tone (DTMF) dialing
“-”: Pulse dialing
Answering machine or fax are connected to the telephone line. To
downlod data, the panel will intercept incoming calls when the
following sequence occurs: 2 rings, hang-up, 10 seconds pause and
another ring.
VU-20N/U voice module is connected to the control panel
Enable/Disable downloading. The parameter is set to “+” by default
(Download disabled).
The first time remote download is required, the master user must
confirm it, as follows: enter the User menu (with the Master code)
and press [Enter] twice ("Wait for ring" screen). This will open a 2
minute window for downloading.
Disarming by telephone is disabled.
The system will report when the Entry delay starts running
The control panel will report on tests when disarmed
Split account is in use: Account #1 events will be reported to
Monitoring Station #1; Account #2 reports from are reported to
Monitoring Station #2.
Use this option only when different account IDs are
required for Double report. If so, it is impossible to assign
different account ID per partition.
If the system is disarmed immediately after alarm, both events are
reported.
To save, press [ENTR]