Hunter-Pro Series & Captain 8 Installation Guide
6.14.2 Single Zone Test
To test a single zone, hardwired or wireless:
1. Set the “E-I” siren indication parameters; see the previous sub-section.
2. Press the desired zone number. The first 8 zones are the onboard outputs and are
named so.
6.14.3 Wireless Test
To test a wireless zone, trigger it. The detector’s reception level (RSSI) is displayed. The level
is also indicated by the speed of the keypad beeps: the faster the beeping the stronger the
reception is.
6.14.4 Set Soak zones
A zone in which false alarms occur can be tested, by setting it as a Soak (or test) zone. A soak
zone does not alarm nor report the Monitoring Station when opened; however, its activity is
being logged.
A zone can be set as soak for no longer than one week. To globaly set the number of soak
days, refer to section 6.7.6, on page 63. When the soak testing time is over, the zone is
automatically reinstated. To manually reinstate a soaked zone, press [#] in the “Zone
Number: X” screen.
6.14.5 Outputs Test
Test the control panel’s and the expander’s outputs, by directly triggering them. Pressing
[ENTR] in any of the output test screens, trips the output for 10 seconds.
Triggering an output directly enables to distinguish between connection and programming
faults: a malfunctioned output that is tested OK, indicates a possible programming error.
To discontinue a test press [END].
Untested Zones:
UT:Zone 12
Untested Zones:
UT: Living Room
Untested Zones:
++++++++++++++++
Untested Zones:
Burglary
ENTR
ENTR
Zone number
Zone name
Zone partitions
Zone type
ENTR
ENTR
Single Zone Test
ENTER/NEXT/END
Press a zone number and open it. The
keypad buzzer should sound beeps.
To see the zone details, proceed.
ENTR
EI
--
0
NEXT ENTR
Test Zone #: 1
Zone 1
ENTR
Test Zone #: 1
On Board Zone
Test Zone #: 1
+---------------
Test Zone #: 1
Burglary
ENTRENTR
Zone type Zone partitions Zone name
Bath window 19
RSSI=3 (3=MAX)
Zone name
Zone number
RSSI level:
1= Weak
2= Good
3= Excellent
Received Signal
Strength Indication