Programming the System
Hunter-Pro Series & Captain 8 Installation Guide
Char.
Parameter
When setting to ‘+’:
F
Enable Fast Arm
Single-key (long press) arming is enabled. Options are:
[1] - Full mode;
[4] - “HOME 1” mode;
[7] - “HOME 2” mode
1
Cancel HOME1 Del
No exit delay when arming to “HOME 1” mode
2
Cancel HOME2 Del
No exit delay when arming to “HOME 2” mode
Z
Disp. Alrm in ON
Alarms will be displayed while the panel is armed
E
EN-50131
In use in some countries
R
Retrigger Opn.Zn
Zones that are open over siren time, will re-trigger the alarm
until they are closed or the panel is disarmed; see also
parameter “B” in section 6.4.2, on page 50.
P
Disp. Armed Part
(+): Armed partitions will be displayed in the “Scan Open
Zones” display mode.
(-): To display armed partitions momentarily (in the “Scan
Open Zones” mode only), press [#]
F
Final door
The exit delay terminates upon closing the final delayed zone
C
Full remote cont
(+): Remote control in mode B is enabled; see section 1,
on page 76.
(-): Remote control in mode A is enabled
Remote control is not available in Captain 8
J
Report W/L Jamm.
Wireless jamming will be reported
A
Part. AutoArming
Auto arming per partitions is enabled
1
O
Beep in disarm
The external siren will beep twice when disarming the panel
(via a keypad)
6.8.3 Third screen
Par.
Name
When setting to ‘+’:
S
DC sirens EOL
DC (only) sirens loops will be EOL resistor supervised for:
Cut, while the panel is disarmed;
Short, while the panel is armed
K
Not in use
-
1
Inactivity auto-arming is set in the User menu; see the User guide for details