Hunter-Pro Series & Captain 8 Installation Guide
The following table lists the output types that have timers and their default times.
* This output type is triggered when a physical output is activated by telephone.
** This output type is triggered when the alarm system is disarmed and the last open zone is
closed. When count down expires the assigned physical output can be used for energy
saving - turning off the lights, for example.
6.7.3 AC report delay
Set a time (in minutes, max. 250) to delay AC fault reports. The default is 15 min.
6.7.4 Phone report delay
Set a time (in minutes) to delay reporting on telephone line faults. Note that if the parameter
“No Dia. tone chck” (see section 6.5.4, on page 59) is disabled, this parameter is negligible.
If the telephone line is usually clear, do not set a delay time.
6.7.5 Burglary report delay
Set a time in seconds (default is zero) to delay reporting on violation of 24-hour zones, if
occurred during the entry delay. The sirens will onetheless sound the alarm. This delay is valid
to all the burglary alarm types. If the panel is disarmed before coundown expires, the event
will not be reported.