Troubleshooting
Hunter-Pro Series & Captain 8 Installation Guide
9.2.4 Auto-arming faults
Make sure that:
1. The auto-arming start time is set correctly (see the Hunter-Pro Series User guide).
2. The system time is accurate.
3. In auto-arming per partition, the right partition is set.
9.2.5 Zone alarm faults
Make sure that:
1. The zone is correctly installed and wired.
2. The zone is not bypassed permanently (see section 6.4.1.1, on page 50).
3. The zone response is set to trigger the sirens (see section 6.4.2, on page 50).
4. The zone is allocated only to one partition (see section 6.4.5, on page 51).
5. The zone sensitivity is correct (see section 6.4.3, on page 51).
6. Zone conditioning time is correct (see section 6.7.8, on page 64).
7. Zone double-knock time is correct (see section 6.7.7, on page 64).
8. Zone is not programmed as soak zone (see section 6.14.4, on page 73).