Hunter-Pro Series & Captain 8 Installation Guide
6.11.2 Local download
The “Local Download” is a standby mode for uploading/downloading data via the COMAX
application; see section 5.2, on page 44, and the COMAX User guide for detailed explanations.
After pressing [ENTR] the panel waits for data packets. Immediately press the “LOCAL” button
in the COMAX.
Wait until “Connected” message is displayed in the COMAX status bar and a beep is sounded.
You can now start uploading/downloading.
6.11.3 Fast Load
The “Fast Load” is a standby mode for downloading system configuration sets via the PRG-
896 fast programmer
1
. The fast programmer can store up to 7 sets for HUNTER-PRO 832 and
4 sets for 8144. Downloading has 2 set options:
1. Full set, to download the whole set/s;
2. Communication set, to download only the communication parameters (taken from the
COMAX's "Communication" tab).
6.12 Key 9: Installer Code
Set or change the Installer code (default, 1234). The code can have up 4 - 6 digits.
The default code must be replaced immediately after installation!
If the first digit of the code is set to zero, it will not be reset in case of
power loss. This is for security reasons.
6.13 Asterisk (*) Key: Fast Programming
To enter the Fast Programming menu, enter the Installer password and press [*].
Following is the Fast Programming screens:
Set the time in hh:mm format
Set the date in dd:mm:yy format
Set up to 4 private (end user) telephone numbers.
Press the asterisk key for ‘+’, ‘*’, ‘#’ and ‘P’ (one second pause).
Set Entry 1 & 2 and the Exit delays
Set the local ('X') and wireless ('W') expanders
1
The sets are uploaded by the COMAX application
9
Installer Code
ENTER/NEXT/END
ENTR
Installer Code
****** (4-6)
3
ENTR ENTR
Timers, Counters
ENTER/NEXT/END
Entry/Exit Delay
ENTER/NEXT/END
Entry 1 2 Exit
20 20 60
ENTR
1
Expanders
ENTER/NEXT/END
ENTRNEXT
Sys Installation
ENTER/NEXT/END
XMW
---
ENTR
Remote Expanders
0