Hunter-Pro Series & Captain 8 Installation Guide
6.14.5.1 In Hunter-Pro Series
Following is the outputs test screens by their order:
Press [ENTR], select an output (press [Next]/[Back]) and
press [ENTR] to trigger it.
Press [ENTR], select an output (press [Next]/[Back]) and
Press [ENTR] to trigger it.
Each I/O-8N expander has one relay output. Each screen
relates to the corresponding expander:
Press [ENTR], select an output (press [Next]/[Back]) and
press [ENTR] to trigger it.
6.14.5.2 In Captain 8
6.14.6 Test MS dialer
Test the Monitoring Station’s PSTN numbers: press [1] to dial to telephone #1; press [2] to
dial to telephone #2, and so on. Pressing a number that is not set results in the error
message: “Check Phone Num. Press END”. After pressing [END] the “Phone Numbers” menu,
where the MS numbers are set, is automatically displayed.
The error “Set Pn. Connect. Press END” is displayed when the “Connected T. Line” parameter
(“P”) in the “Communication Options” menu is set as “-”; see section 6.5.4, on page 54.
6.14.7 Test MS GSM
Test the Monitoring Station’s GSM numbers. The test is similar to the previous PSTN test.
6.14.8 Test MS Radio
Test the radio communication with the Monitoring Station. Press [ENTR] to trigger a test report.
An ACK cannot be received from the Monitoring Station in this test.
6.14.9 GSM signal strength
Check the GSM network signal strength. The reception level is indicated by squares, as in a
cell phone: the more there are squres, the better is the reception, and the opposite.