145
NO.
Parameter
Name
Setting Range default
WRT
User
setting
f351
Bias of
analog
output
0~100% 0
f352
output
frequency
when AO =
0V
0 Hz ~f007 0.0
f353
output
frequency
when AO =
10V
0 Hz ~f007 0.0
f354
AO1 bias 0~255 128
f355
Input
terminal
function for
LI5
See f301 0
f363
Factory
reserved
[-f4-]
NO.
Parameter
Name
Setting Range default
WRT
User
setting
f400 Retry selection
0: disabled
1~10 times.
0
f401
Electronic-
thermal
protection
characteristic
selection
0
Trip enable
stall
disable (standard
motor)
1
Trip enable
stall
enable (standard
motor)
2
Trip disable
stall
disable (standard
motor)
3
Trip disable
stall
enable (standard
motor)
5
Trip enable
stall
disable (forced
cooling motor)
2

Table of Contents