INSTRUCTION MANUAL
IMUX 2000
Intelligent E1 Multiplexer
With Redundant Capability
NOTICE
IMUX 2000E1 RFL Electronics Inc.
July 22, 2008 i 973.33
4.3100
The information in this manual is proprietary and confidential to RFL Electronics Inc.
Any reproduction or distribution of this manual, in whole or part, is expressly
prohibited, unless written permission is given by RFL Electronics Inc.
This manual has been compiled and checked for accuracy. The information in this
manual does not constitute a warranty of performance. RFL Electronics Inc. reserves
the right to revise this manual and make changes to its contents from time to time. We
assume no liability for losses incurred as a result of out-of-date or incorrect information
contained in this manual.
Note: This product is covered by US Patent number 7,061,905
RFL Electronics Inc.
353 Powerville Road Boonton Twp., NJ 07005-9151 USA
Tel: 973.334.3100 Fax: 973.334.3863
Email: sales@rflelect.com
www.rflelect.com
Publication Number MC 2000CM4-E1
Printed in U.S.A.
Revised July 22, 2008

Table of Contents

Other manuals for RFL IMUX 2000

Questions and Answers

  • K
    kellyginaAug 17, 2025
    What to do if RFL IMUX 2000 Multiplexer has equipment problems?
    • J
      Jaime SchmidtAug 17, 2025
      If you are experiencing equipment problems with the RFL Multiplexer, replace the faulty module or modules with spares.
  • H
    hbutlerAug 19, 2025
    What to do if there are setup problems with RFL IMUX 2000?
    • A
      Anna ChapmanAug 19, 2025
      If you are experiencing setup problems with the RFL IMUX 2000 Multiplexer, reconfigure the multiplexer or multiplexers that are not set up correctly.
  • K
    Kristie FrostAug 22, 2025
    What to do if RFL IMUX 2000 has public network problems?
    • A
      Ashley WhiteAug 22, 2025
      If you are experiencing public network problems with the RFL Multiplexer, work with your Local or Inter-exchange carrier to correct the situation.
  • A
    Andrew MayAug 26, 2025
    What to do if RFL Multiplexer has private network problems?
    • A
      aaron34Aug 26, 2025
      If you are experiencing private network problems with the RFL Multiplexer, consult the network manager.
  • B
    Bethany VasquezAug 28, 2025
    What to do if RFL Multiplexer has channel troubles?
    • E
      Erin HunterAug 28, 2025
      If you are experiencing channel troubles with the RFL IMUX 2000 Multiplexer, check to see if similar troubles exist on other channels. The cause is probably a E1 circuit or IMUX 2000 Common Module failure.
  • J
    James WrightAug 30, 2025
    What to do for low bit error rate on a data channel of RFL IMUX 2000 Multiplexer?
    • M
      Megan SmithAug 30, 2025
      If you are experiencing a low bit error rate on a data channel with the RFL Multiplexer, try in-service E1 circuit monitoring before performing out-of-service testing.
  • B
    brodriguezSep 2, 2025
    What to do if RFL IMUX 2000 has E1 circuit errors?
    • J
      jonesscottSep 2, 2025
      If you are experiencing E1 circuit errors with the RFL Multiplexer, perform in-service monitoring on the E1 facility.
  • A
    awyattSep 4, 2025
    What to do if RFL IMUX 2000 has Loss of Carrier at the Common Module?
    • M
      Megan DavidsonSep 5, 2025
      If you are experiencing Loss of Carrier at the Common Module of RFL Multiplexer, check for presence of carrier. The cause may be low received signal power level or low 1’s density.
  • K
    Kelsey HarringtonSep 8, 2025
    What to do if RFL IMUX 2000 Multiplexer has high error rate or loss of frame synchronization?
    • L
      Lisa BarberSep 8, 2025
      If you are experiencing a high error rate or loss of frame synchronization with the RFL Multiplexer, use the loopback procedure to isolate the fault.
  • M
    Mrs. Melissa Green DDSSep 12, 2025
    What to do if RFL IMUX 2000 has power-related problem?
    • O
      olivia31Sep 12, 2025
      If you are experiencing a power-related problem with the RFL IMUX 2000 Multiplexer, verify that the POWER LED on the IMUX 2000 Main Shelf is on. The cause is that the POWER LED is off.

RFL IMUX 2000 Specifications

General IconGeneral
BrandRFL
ModelIMUX 2000
CategoryMultiplexer
LanguageEnglish

Related product manuals