Because RFL™ and Hubbell® have a policy of continuous product improvement, we reserve the right to change designs and specifications without notice.
DACS/ILS Diagnostics*:
DACS/ILS count of received all ones
DACS/ILS count of received remote alarm
DACS/ILS count of received carrier loss
DACS/ILS count of received loss of sync
DACS/ILS count of received bipolar violation
DACS/ILS count of received elastic store slips
DACS/ILS count of received bit error
DACS/ILS count of received multiframe out of sync
* Only pertains to systems using DACS or ILS
The Sequence of Events log can be accessed by the user via the Network Management Software (See
Section 4) or via the Simple Command Language (See Section 5).
2.3.3.12 Time and Date Settings
This function allows a user to set or read the time and date set in the CM4 using the NMS or SCL
commands. The CM4 uses the time and date settings to time stamp events as they occur. See paragraph
2.3.3.11 and Section 5 for more information.
2.3.3.13 Download Function
The download function allows a user to update CM4 application code by using a terminal emulation
package containing the XMODEM transfer protocol.. Contact RFL customer service for more
information.
IMUX 2000E1 RFL Electronics Inc.
April 1, 2007 2-17 (973) 334-3100