Because RFL and Hubbell® have a policy of continuous product improvement, we reserve the right to change designs and specications without notice.
Figure 9-6. Testing channel modules using a local E1 loopback
LOCATION 1
ANALOG OR
DATA TEST SET
IN
OUT
VOICE
AND
DATA
CIRCUITS
EQUIPMENT
LOOPBACK
OR
MANUAL
LOOPBACK
(PATCHCORD)
E1 OUT
E1 IN
DSX-1
or
EQUIP
JACKS
IMUX 2000
IN
OUT
IMUX 2000E1 RFL Electronics Inc.
January 23, 2004 9-9 (973) 334-3100