EasyManua.ls Logo

RFL IMUX 2000 - Page 362

RFL IMUX 2000
1105 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Because RFL and Hubbell® have a policy of continuous product improvement, we reserve the right to change designs and specications without notice.
RFL DA-191A RFL Electronics Inc.
July 23, 2001 7 (973)
334-3100
14. After completing the above procedures, set the module for local control or remote control
operation using the following steps.
A. For local control operation:
1. Set to local control: REMOTE switch (SW2-5) UP.
2. Turn service on: OFF switch (SW2-6) UP.
3. Insert the module into the selected slot in the multiplexer. The module must be
inserted so that the white ejector tab is at the bottom in a full size (5¼" high)
shelf.
B. For remote control operation:
1. Set to local control: REMOTE switch (SW2-5) UP.
2. Turn service off: OFF switch (SW2-6) DOWN.
3. Insert the module into the selected slot in the multiplexer. The module must be
inserted so that the white ejector tab is at the bottom in a full size (5¼" high)
shelf.
4. Wait 15 seconds; this loads the parameter settings for the card into the shelf
common module.
5. Remove the module and set to remote control: REMOTE switch
(SW2-5)DOWN. Do not turn service on.
6. Reinstall the module.
7. Verify the configuration via remote control by issuing a CONFIG? query. See
Section on Remote Control Interface for an explanation of the CONFIG?
response.
8. Set service on via remote control (SCL SET command, with “SRVC = ON” in
the parameter field). You can now change the operating parameters for the
module using SCL commands. For details on using the Simple Command
Language (SCL) for remote access and control, consult your multiplexer
operation manual.

Table of Contents

Other manuals for RFL IMUX 2000

Related product manuals