USING SERVICE PROGRAM MODE
B044/B045/B046 5-20 SM
7
Mode Number/Name Function/[Setting]
ROM Versions and Option Connections
Note: SP7-801 cannot be accessed at the screen. This information appears on SMC
printouts only. (Go to SP5-992 and select "2" to print out all data. The SP-801
information will appear in the "LOG DATA" section on the second page of the printout.
[
☛
5.1.5])
Shows software versions and option connection statuses.
1 Firmware Version
2 No meaning (Fixed at "VER. 1")
3 Fax Unit ["Yes" = installed, "No" = Not installed]
4 Printer Unit ["Yes" = installed, "No" = Not installed]
5 ADF ["Yes" = installed, "No" = Not installed]
6 Optional Memory ["No" (None installed), "32MB", "40MB", "64MB"]
7 Paper Tray Unit ["Yes" = installed, "No" = Not installed]
801
8 Bypass Type ["1" = 1 sheet / "100" = 100-sheet]
PM Counter Display803*
1 Displays the PM counter value (the count since the last
PM).
PM Counter Reset804
1 Resets the PM counter.
[0 = No / 1 = Yes]
After selecting “1”, hold down the Original Type key and
press the OK key (or ' key) to execute the reset. If the
reset is successful, the display shows “Action completed.”
If the reset fails, the display shows “Error!!!”.
SC/Jam Counter Reset807
1 Resets the SC counter and all jam counters.
[0 = No / 1 = Yes]
After selecting “1”, hold down the Original Type key and
press the OK key (or ' key) to execute the reset. If the
reset is successful, the display shows “Action completed.”
If the reset fails, the display shows “Error!!!”.
808 Reset Counters
1 Resets all counters, except for the total counter (SP7-
003).
[0 = No / 1 = Yes]
After selecting “1”, hold down the Original Type key and
press the OK key (or ' key) to execute the reset. If the
reset is successful, the display shows “Action completed.”
If the reset fails, the display shows “Error!!!”.