USING SERVICE PROGRAM MODE
SM 5-21 B044/B045/B046
Service
Tables
7
Mode Number/Name Function/[Setting]
825 Total Counter Reset
1 Resets the electronic total counter.
[0 = No / 1 = Yes]
• This reset is generally performed at installation. This SP
mode is effective only once, while the counter still has a
negative value. This SP cannot be used once the
counter takes a positive value.
• After selecting “1”, hold down the Original Type key and
press the OK key (or ' key) to execute the reset. If the
reset is successful, the display shows “Action
completed.” If the reset fails, the display shows “Error!!!”.
SC History Display901
1 Displays the codes of the last fifty errors that have
occurred.
[0 = No / 1 = Yes]
On fax-equipped models, you can print out the last fifty
error codes using fax service mode 04. For information,
refer to the fax service manual.
SC History Reset902
1 Clears the SC history.
[0 = No / 1 = Yes]
• Note that when executed on fax-equipped models, this
operation will not clear the machine's service-report
data.
• After selecting “1”, hold down the Original Type key and
press the OK key (or ' key) to execute the reset. If the
reset is successful, the display shows “Action
completed.” If the reset fails, the display shows “Error!!!”.
PCU Counter Display908
1
Displays the number of prints made since the PCU was
last replaced.
PCU Counter Reset909
1 Resets the developer counter.
[0 = No / 1 = Yes]
After selecting “1”, press the Original Type key and the
OK key (or ' key) at the same time to execute the reset.
If the reset is successful, the display shows “Action
completed.” If the reset fails, the display shows “Error!!!”.
ID Sensor Error Counter Display911*
1 Displays the total number of logged ID sensor errors.
For information about how to analyze these errors, see
Section 5.1.11.
ID Sensor Error Counter Reset912
1 Resets the ID sensor error counter.
[0 = No / 1 = Yes]
After selecting “1”, hold down the Original Type key and
press the OK key (or ' key) to execute the reset. If the
reset is successful, the display shows “Action completed.”
If the reset fails, the display shows “Error!!!”.