BIT SWITCHES
B465 5-10 SM
System Switch 03
No. FUNCTION COMMENTS
0–7 Length of time that RDS is
temporarily switched on when bits 6
and 7 of System Switch 02 are set
to "User selectable"
00 - 99 hours (BCD).
This data is only valid if bits 6 and 7 of System
Switch 02 are set to "User selectable".
The default setting is 24 hours.
System Switch 04
No. FUNCTION COMMENTS
0–2 Not used Do not change these settings.
3 Dedicated transmission parameter
programming
0: Disabled 1: Enabled
Set this bit to 1 before changing any dedicated
transmission parameters.
4 Not used Do not change the setting.
5
Replacement level for the
maintenance kits
0: User 1: Service
0: The machine asks the user to replace the
parts in the ADF maintenance kit after
45,000 scans with the ADF.
After the user replaces the parts, the machine
asks the user if they have been replaced or
not. After the user answers yes, the user has
to reset the roller counter using the key
operator tools.
The replacement counter is programmed at
the following addresses:
ADF kit counter: 4002D0 to 4002D3(H)
Refer to section 5.5 for more details.
1: The machine will not ask the user to
replace the maintenance kits.
6 CSI programming level
0: User level 1: Service level
1: Only a service function can program the
CSI.
7
Telephone line type programming
mode
0: User level 1: Service level
1: Only a service function can program the
telephone line type selection.
System Switch 05
No. FUNCTION COMMENTS
0–7 Not used Do not change these settings.