BIT SWITCHES
B465 5-22 SM
Communication Switch 03
No. FUNCTION COMMENTS
0–7 Maximum number of page
retransmissions in a memory
transmission
00 - FF (Hex) times.
This setting is not used if ECM is switched on.
Default setting - 03(H)
Communication Switch 04 - Not used (do not change any of these settings)
Communication Switch 05 - Not used (do not change any of these settings)
Communication Switch 06
No. FUNCTION COMMENTS
0–5 Not used Do not change these settings.
6 Dialing requirements: USA
0: Disabled 1: Enabled
7 DTS requirements: Germany
0: Disabled 1: Enabled
This function automatically sets these switches to
the required settings for each country after
selecting a country code (System switch 0F).
Communication Switch 07 - Not used (do not change any of these settings)
Communication Switch 08 - Not used (do not change any of these settings)
Communication Switch 09 - Not used (do not change any of these settings)
Communication Switch 0A
No. FUNCTION COMMENTS
0 Point of resumption of
memory transmission upon
redialing
0: From the error page
1: From page 1
0: The transmission begins from the page where
transmission failed the previous time.
1: Transmission begins from the first page, using
normal memory transmission.
1–6 Not used Do not change these settings.
7
Emergency calls using 999
0: Enabled 1: Disabled
Hong Kong only
If this bit is at 1, the machine will not allow you to
dial 999 at the auto-dialer.
Communication Switch 0B - Not used (do not change any of these settings)
Communication Switch 0C - Not used (do not change any of these settings)