System SP Table-1
D009/D011/D012/D013/D091/D092 4-8 SM Appendix
038 Feed Waiting: Maximum Time
Sets the maximum feed waiting time.
[0 to 30 / 0 / 1 sec]
The paper is fed when the time specified
with this SP has passed even though the
fusing temperature has not reached the
prescribed temperature.
0: Disabled.
1106 Fusing Temperature Display
001 Roller Center Displays the temperature of the fusing
unit.
[-20 to 250 / 0 / 1 deg]
002 Roller Ends
003 Machine Inside at Power On Displays the temperature inside the
machine.
[-20 to 250 / 0 / 1 deg]
004 Machine Inside
1109*
Fusing Nip Band Check
Checks the fusing nip band.
001 Execution
002
Idling Rotation Time
[0 to 120 / 60 / 1 sec]
Specifies the fusing rotation time before executing SP1109-001.
003
Pre-Idling Time
[5 to 30 / 10 / 1 sec]
Specifies the time that the paper stops in the fusing unit for measuring the
nip.