System SP Table-6
D009/D011/D012/D013/D091/D092 4-156 SM Appendix
6016*
Original Size Detection Priority
Specifies the original size for a size detected by the original sensor, since
original sensors cannot recognize all sizes.
001
Original Size Detection
Priority
[0 or 1 / 0 / - ]
0: Setting 1
1: Setting 2
NA
Setting 1 Setting 2
DLT SEF
Folio SEF
11" x 15"
LG SEF Foolscap SEF
LT SEF US EXE 8" x 10"
LT LEF US EXE LEF
EU/
ASIA
DLT SEF
8K
267 x 390 mm
LT SEF
16K
195 x 267 mm
LT LEF
16K
267 x 195 mm
6017*
Sheet Through Magnification
[–5 to 5 / 0 / 0.1% step]
Adjusts the magnification in the sub-scan direction for ADF mode.
Use the key to toggle between + and - before entering the value