Service Call 
 
M0C3/M0C4/M0C5/M0C6/M0C7  6-4  SM 
 
No.  Type  Error Name/Error Condition/Major Cause/Solution 
SC220  D  Beam synchronization error 
The laser synchronization detection signal for the LD is not output within 0.4 sec. 
after the laser unit has turned on. 
•  Disconnected cable from the laser synchronization detector defective 
connection 
•  Defective laser synchronization detector/ main board 
•  The beam does not enter the laser synchronization detector 
1.  Turn the power OFF and ON. 
2.  Replace the polygon mirror motor/ laser unit. 
3.  Replace the interface harness of the laser unit. 
4.  Replace the main board. 
 
No.  Type  Error Name/Error Condition/Major Cause/Solution 
SC268  D  Laser unit thermistor error 
•  The laser unit thermistor detected a temperature lower than -30°C for more 
than 4 sec. 
•  The laser unit thermistor detected a temperature higher than 105°C for more 
than 1 sec. 
•  Thermistor disconnected (causes an extremely low temperature reading) 
•  Defective harness 
•  Defective main board 
1.  Turn the power OFF and ON. 
2.  Replace the laser unit thermistor.